[Play] [Pause] [Stop]
FINAL INGRESS
1

On MCC-M GO Open ATV Hatch into intermediate position, Report to MCC-M and ingress ATV

2

Remove and stow the curtain

3

Secure the hatch to the full open position

4

Activate MLU

5

If scrubbing was performed

  1. Switch off WPO. Check LED is off
  2. Disconnect PSIF power and grounding cable from WPO
  3. Disconnect scrubber power and grounding cable from PSIF
  4. Remove PSIF and store it
6
  1. Remove scrubber
  2. Install scrubber filter cover
  3. Stow scrubber
7

Perform sampling using AK-1M

8

Verify Cabin Return Grid and take photos to document level of filter contamination

9

Retrieve air duct

10

Check ВПрК is off

11

Connect air duct to ВПрК Fan

12

Deploy and secure air duct to the rack struts inside ATV using velcro strips

13

Connect air duct grounding

14

Stow ВД bag

15

Switch on ВПрК and check air flow from the air duct

16

Retrieve and install ИПК-1М

17

Retrieve and install OKP-1

18

Retrieve handrails and install them on seat tracks

19

Fan vibration reduction

20

Install acoustic covers on CRG

Refer to ATV Cleaning Procedure as needed
21

Install ИП-1 sensors on ПрК-СУ hatch

22

Update IMS at the end of the equipment installation and Report to MCC-M

23

On RS laptop ATV ECLSS display: If needed, send command to configure ATV ECLSS to attached mode